Physical Weight: 10 ounces Size: 2.5 W x 4.75 H x 1.25 D inches (63.5 W 120.7 H x 31.8 D mm) Operating Temperature: -20° to 120° F (-30° to 50° C) Case: Extruded aluminum body / nickel plated aluminum end caps.
Resistant to impact and environmentally sealed. Keypad Sealed membrane that is resistant to both water and petroleum products.
Nine tactile-feedback keys. Transducer Dual element (transmit and receive). 1 to 10 MHz frequency range.
Special high damped transducers available for use with through paint or coating measurements).
Locking quick disconnect LEMO connectors.
4 foot cable.
Optional cable lengths up to 100 feet. Custom transducers available for special applications. | Power Source Two 1.5V alkaline or 1.2V NiCad AA cells Typically operates for 200 hours on alkaline and 130 hours on NiCad. Display flashes when battery is low. Unit turns off automatically when battery is too low to operate reliably. Display Multi-function 4.5 digit liquid crystal display with 0.500 inch numerals, backlit for use in poor light conditions. Backlight is selectable: on / off / auto ( illuminates only when taking a measurement ). Measurements displayed in inches, inches/microsecond. millimeters, and mters/second. Bar graph indicates stability of reading. Certification
Factory calibration traceable to national standards. Warranty 5 year limited | Measuring Range:
Pulse Echo Mode(Pit & Flaw Detection): Measures from 0.025 to 19.999 inches (0.63 to 500 millimeters).
Echo Echo Mode (Thru Paint & Coatings): Measures from 0.100 to 1.0 inches (2.54 to 25.4 millimeters).
Switch to select English or metric units. Resolution: 0.001 inches (0.01 millimeters) Velocity Range: .0492 to .3937 in/microsec (1250 to 10,000 meters/sec). Built in: Stainless steel reference disk for probe zeroing. Four readings per second for single point measure ments or 16 per second in scan mode – captures the minimum thickness. Single and Two point calibration option included. Features
Multi-Mode: Toggle between Pit/Flaw detection (Pulse Echo Mode), and through Paint/Coatings (Echo-Echo Mode) with the single press of a button. Alarm Mode: Enter a minimum acceptable thickness value. If measurement falls below minimum, red led will illuminate and sound beeper. If measurement is above minimum value, green led will illuminate. Data Ouput: RS232 output sends thickness readings to a computer or other external storage device. |